Features:
- 200MHz bandwidths
- 1GSa/s Real Time sample rate
- Large (7.0-inch) color display,WVGA(800x480)
- Record length up to 40K
- Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.
- USB host and device connectivity, standard
- Multiple automatic measurements
- Four math functions, including FFTs standard
- Provides software for PC real-time analysis
- VGA Optional
Specifications:
Model |
DSO5202P |
Acquisition |
|
Sample Rate |
Real-Time Sample: 1GS/s |
Acquisition Modes |
|
Normal |
Normal data only |
Peak Detect |
High-frequency and randon glith capture |
Average |
Wavefom Average, selectable 4,8,16,32,64,128 |
Inputs |
|
Inputs Coupling |
AC, DC, GND |
Inputs Impendance |
1MΩ±2% ?20pF±3pF |
Probe Attenuation |
1X, 10X |
Supported Probe Attenuation Factor |
1X, 10X, 100X, 1000X |
Maximum Input Voltage |
CAT I and CAT II: 300VRMS (10×), Installation Category; |
Horizontal System |
|
Sample Rate Range |
500MS/s--1GS/s |
Waveform Interpolation |
(sin x)/x |
Record Length |
40K |
SEC/DIV Range |
2ns/div to 40s/div |
Sample Rate and |
±50ppm(at over any â‰?ms time interval) |
Position Range |
2ns/div to 10ns/div; (-4div x s/div) to 20ms; |
Delta Time Measurement Accuracy |
Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns); |
Vertical System |
|
Vertical Resolution |
8-bit resolution, all channel sampled simultaneously |
Position Range |
2mV/div to 10V/div |
Bandwidth |
200MHz |
Rise Time at BNC( typical) |
1.8ns |
Analog Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled |
2mV/div to 20mV/div, ±400mV; 50mV/div to 200mV/div, ±2V |
Math |
+, -, *, /, FFT |
FFT |
Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman; |
Bandwidth Limit |
20MHz |
Low Frequency Response (-3db) |
�0Hz at BNC |
DC Gain Accuracy |
±3% for Normal or Average acquisition mode, 5V/div to 10mV/div; |
DC Measurement Accuracy, |
When vertical displacement is zero, and N â‰?6:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected; |
Volts Measurement Repeatability, |
Delta volts between any two averages of �6 waveforms acquired under same setup and ambient conditions |
Trigger System |
|
Trigger Types |
Edge, Video, Pulse, Slope, Over time, Alternative |
Trigger Source |
CH1, CH2, EXT, EXT/5, AC Line |
Trigger Modes |
Auto, Normal, Single |
Coupling Type |
DC, AC, Noise Reject, HF Reject, LF Reject |
Trigger Sensitivity |
DC(CH1,CH2): |
Trigger Level Range |
CH1/CH2: ±8 divisions from center of screen; |
Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times �0ns |
CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen; |
Set Level to 50%(typical) |
Operates with input signals �0Hz |
Video Trigger |
|
Video Trigger Type |
CH1, CH2: Peak-to-peak amplitude of 2 divisions; |
Signal Formats and Field Rates, Video Trigger Type |
Supports NTSC, PAL and SECAM broadcast systems for any field or any line |
Holdoff Range |
100ns ~ 10s |
Pulse Width Trigger |
|
Pulse Width Trigger Mode |
Trigger when (< , >, = , or �; Positive pulse or Negative pulse |
Pulse Width Trigger Point |
Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level. |
Pulse Width Range |
20ns ~ 10s |
Slope Trigger |
|
Slope Trigger Mode |
Trigger when (< , > , = , or �); Positive slope or Negative slope |
Slope Trigger Point |
Equal: The oscilloscope triggers when the waveform slope is equal to the set slope. |
Time Range |
20ns ~ 10s |
Overtime Trigger |
|
Over Time Mode |
Rising edge or Falling edge |
Time Range |
20ns ~ 10s |
Alternative Trigger |
|
Trigger on CH1 |
Internal Trigger: Edge, Pulse Width, Video, Slope |
Trigger on CH2 |
Internal Trigger: Edge, Pulse Width, Video, Slope |
Trigger Frequency Counter |
|
Readout Resolution |
6 digits |
Accuracy (typical) |
±30ppm (including all frequency reference errors and ±1 count errors) |
Frequency Range |
AC coupled, from 4Hz minimum to rated bandwidth |
Signal Source |
Pulse Width or Edge Trigger modes: all available trigger sources |
Measure |
|
Cursor Measurement |
Voltage difference between cursors: ?V |
Auto Measuerment |
Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF |
Display |
|
Display Type |
7 inch 64K color TFT (diagonal liquid crystal) |
Display Resolution |
800 horizontal by 480 vertical pixels |
Display Contrast |
Adjustable (16 gears) with the progress bar |
Probe Compensator Output |
|
Output Voltage( typical) |
About 5Vpp into â‰?MΩ load |
Frequency(typical) |
1kHz |
Power Supply |
|
Supply Voltage |
100-120VACRMS(±10%), 45Hz to 440Hz, CAT? |
Power Consumption |
<30W |
Fuse |
2A, T rating, 250V |
Environmental |
|
Temperature |
Operating: 32? to 122? (0? to 50?); |
Cooling Method |
Convection |
Humidity |
+104? or below (+40? or below): �0% relative humidity; |
Altitude |
Operating: Below 3,000m (10,000 feet); |
Mechanical |
|
Size |
Length 385mm, Width 200mm, Height 245mm |
Weight |
3.5KG(with Packing); 2.08KG(without Packing) |
Package List:
- 1xDigital storage Oscilloscope
- 1xOscilloscope Probe Kit two sets
- 1xOscilloscope powerline
- 1xHantek data CD & Warranty Card customer return receipt & Manufacturer certificate
- 1xUSB line